Numerical Study of GFRP-reinforced Concrete Beams with Straight and Hooked-end Bar Lap Splices
Source: By:Sara Mirzabagheri, Osama (Sam) Salem
DOI: https://doi.org/10.30564/jbms.v6i1.6170
Abstract:Glass fibre-reinforced polymer (GFRP) has been increasingly used as the main reinforcement in concrete structures due to its durability and resistance to corrosion. However, there is a lack of data regarding the bond behaviour of GFRP bars with 180-degree hooked ends used in flexure concrete elements. To investigate the effects of the hooked ends of GFRP bars on the bond strength with concrete, beams reinforced with GFRP bars with straight and hooked-end lap splices at the midspan were modelled using ABAQUS/Standard software. The finite element models were validated using the experimental results of four full-size concrete beams. Two beam specimens had straight-end bars, while the other two had hooked-end bars. Sensitivity analysis was performed to find the proper values for model verification, such as dilation angle and mesh density. According to the outcomes of the parametric study conducted in this research, changing the length of the bar lap splices in the range of 15 to 40 times the bar diameter had a negligible effect on the beam’s overall behaviour. Increasing the number of reinforcing bars from 3 to 5 increased the beam flexural strength by about 33%, whereas increasing the diameter of the bars from 10 to 20 mm doubled the beam strength.
References:[1] Long-term Performance of GFRP Reinforcement [Internet]. Texas Transportation Institute. Available from: https://rosap.ntl.bts.gov/view/dot/17628/dot_17628_DS1.pdf [2] Ehsani, M.R., Saadatmanesh, H., Tao, S., 1996. Design recommendation for bond of GFRP rebars to concrete. Journal of Structural Engineering. 122(3), 247–254. DOI: https://doi.org/10.1061/(ASCE)0733-9445(1996)122:3(247) [3] Morphy, R.D., 1999. Behaviour of fiber reinforced polymer (FRP) stirrups as shear reinforcement for concrete structures [Master' s thesis]. Winnipeg: University of Manitoba. [4] Yang, J.M., Min, K.H., Shin, H., et al., 2012. Effect of steel and synthetic fibers on flexural behaviour of high-strength concrete beams reinforced with FRP bars. Composites Part B Engineering. 43(3), 1077–1086. DOI: https://doi.org/10.1016/j.compositesb.2012.01.044 [5] Rehabilitation of Concrete Structures with CFRP Strips Glued into Slits [Internet]. Available from: https://citeseerx.ist.psu.edu/document?repid=rep1&type=pdf&doi=1175338445b942b34ee2f33f735605c02bf972ff [6] Nanni, A., Alkhrdaji, T., Barker, M., et al. (editors), 1999. Overview of testing to failure program of a highway bridge strengthened with FRP composites. Proceeding of 4th International Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures (FRPRCS-4); 1999 Oct 31–Nov 5; Baltimore, MD. [7] Wu, Z., Yuan, H., Hideki, Y., et al., 2001. Experimental/analytical study on interfacial fracture energy and fracture propagation along FRP-concrete interface. ACI International. 201, 133–152. DOI: https://doi.org/10.14359/10762 [8] Yao, J., Teng, J.G., Chen, J.F., 2004. Experimental study on FRP to concrete bonded joints. Composites Part B: Engineering. 36(2), 99–113. DOI: https://doi.org/10.1016/j.compositesb.2004.06.001 [9] De Lorenzis, L., La Tegola, A., 2003. Analytical modeling of splitting bond failure for NSM FRP reinforcement in concrete. Fibre-reinforced polymer reinforcement for concrete structures. World Scientific Publishing: Singapore. pp. 975–984. [10] Yuan, H., Teng, J.G., Seracino, R., et al., 2004. Full-range behavior of FRP-to concrete bonded joints. Engineering Structures. 26(5), 553–565. DOI: https://doi.org/10.1016/j.engstruct.2003.11.006 [11] Sharaky, I.A., Torres, L., Comas, J., et al., 2014. Flexural response of reinforced concrete (RC) beams strengthened with near surface mounted (NSM) fibre reinforced polymer (FRP) bars. Composite Structures. 109, 8–22. DOI: https://doi.org/10.1016/j.compstruct.2013.10.051 [12] Fillmore, B., Sadeghian, P., 2018. Contribution of longitudinal glass fiber-reinforced polymer bars in concrete cylinders under axial compression. Canadian Journal of Civil Engineering. 45, 458–468. DOI: https://doi.org/10.1139/cjce-2017-0481 [13] Mirzabagheri, S., Tasnimi, A.A., Issa, F., 2018. Experimental and numerical study of reinforced concrete interior wide beam-column joints subjected to lateral load. Canadian Journal of Civil Engineering. 45(11), 947–957. DOI: https://doi.org/10.1139/cjce-2018-0049 [14] Mirzabagheri, S., Tasnimi, A.A., 2019. Evaluation of CSA and ACI shear strength factor for RC roof wide and conventional beam-column joints. Ingegneria Sismica. 36(1). [15] Yang, F., 2014. Deformation behaviour of beams reinforced with fibre reinforced polymer bars under bending and shear [Ph.D. thesis]. Sheffield: University of Sheffield. [16] Stoner, J.G., 2015. Finite element modelling of GFRP reinforced concrete beams [Master’s thesis]. Waterloo: University of Waterloo. [17] Roudsari, S., Hamoush, S., Soleimani, S., et al., 2018. Analytical study of reinforced concrete beams strengthened by FRP bars subjected to impact loading conditions. arXiv preprint arXiv:1806.06929. DOI: https://doi.org/10.48550/arXiv.1806.06929 [18] Elchalakani, M., Karrech, A., Dong, M., et al., 2018. Experiments and finite element analysis of GFRP reinforced geopolymer concrete rectangular columns subjected to concentric and eccentric axial loading, Structures. 14, 273–289. DOI: https://doi.org/10.1016/j.istruc.2018.04.001 [19] Raza, A., Zaman Khan, Q.u., Ahmad, A., 2019. Numerical investigation of load-carrying capacity of GFRP-reinforced rectangular concrete members using CDP model in ABAQUS. Advances in Civil Engineering. DOI: https://doi.org/10.1155/2019/1745341 [20] Aly, R., Benmokrane, B., Ebead, U., 2006. Tensile lap splicing of fiber-reinforced polymer reinforcing bars in concrete. ACI Structural Journal. 857–864. [21] Esfahani, M.R., Rakhshanimehr, M., Mousavi, R., 2013. Bond strength of lap-spliced GFRP bars in concrete beams. Journal of Composites for Construction. 17(3), 314–323. DOI: https://doi.org/10.1061/(ASCE)CC.1943-5614.0000359 [22] Wu, C., Hwang, H.J., Ma, G., 2022. Effect of stirrups on the bond behavior of lap spliced GFRP bars in concrete beams. Engineering Structures. 266, 114552. DOI: https://doi.org/10.1016/j.engstruct.2022.114552 [23] Abbas, H., Elsanadedy, H., Alaoud, L., et al., 2023. Effect of confining stirrups and bar gap in improving bond behavior of glass fiber reinforced polymer (GFRP) bar lap splices in RC beams. Construction and Building Materials. 365, 129943. DOI: https://doi.org/10.1016/j.conbuildmat.2022.129943 [24] Nour, O., Salem, O., Mostafa, A., 2022. Experimental testing of GFRP-reinforced concrete beams with mid-span lap splices utilizing straight- and hooked-end bars. Lecture notes in civil engineering (LNCE). Springer: Cham. DOI: https://doi.org/10.1007/978-3-031-09409-5_12 [25] ABAQUS 6.14: Analysis User’s Guide [Internet]. Available from: https://www.academia.edu/28334906/Abaqus_Analysis_Users_Guide/ [26] Maekawa, K., Pimanmas, A., Okamura, H., 2003. Nonlinear mechanics of reinforced concrete. CRC Press: Boca Raton. [27] Eurocode 2: Design of Concrete Structures-Part 1-2: General Rules- Structural Fire Design (EN 1992-1-2) [Internet]. European Standard. Available from: https://www.phd.eng.br/wp-content/uploads/2015/12/en.1992.1.2.2004.pdf [28] Poliotti, M., Bairan, J.M., 2019. A new concrete plastic-damage model with an evolutive dilatancy parameter. Engineering Structures. 189, 541–549. DOI: https://doi.org/10.1016/j.engstruct.2019.03.086 [29] Wosatko, A., Winnicki, A., Polak, M.A., et al., 2019. Role of dilatancy angle in plasticity-based models of concrete. Archives of Civil and Mechanical Engineering. 19(4), 1268–1283. DOI: https://doi.org/10.1016/j.acme.2019.07.003 [30] Benmokrane, B., Theriault, M., Masmoudi, R., et al., 2003. Effect of reinforcement ratio on concrete members reinforced with FRP bars. [31] Kattan, P.I., Voyiadjis, G.Z., 2007. Effect of reinforcement ratio on damage in reinforced concrete beams—A damage mechanics approach. Jordan Journal of Civil Engineering. 1(1), 73–82. [32] El-Azab, A., Mohamed, H.M., 2014. Effect of tension lap splice on the behaviour of high strength concrete (HSC) beams. HBRC Journal. 10(3), 287–297. DOI: https://doi.org/10.1016/j.hbrcj.2014.01.002 [33] Canadian Standard Association, 2012. Design and construction of building structures with fibre-reinforced polymers (CSA-S806-12). CSA Group: Mississauga, Ontario. [34] Szczech, D., Kotynia, R., 2018. Beam bond tests of GFRP and steel reinforcement to concrete. Archives of Civil Engineering. 64(4), 243–256. DOI: https://doi.org/10.2478/ace-2018-0072